Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 153 2018-05-08
9.2.2 AT+HTTPTERM Terminate HTTP Service
AT+HTTPTERM Terminate HTTP Service
Test Command
AT+HTTPTER
M=?
Response
OK
Execution
command
AT+HTTPTER
M
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Mode
NO_SAVE
Time
-
Reference
Note
9.2.3 AT+HTTPPARA Set HTTP Parameters Value
AT+HTTPPARA Set HTTP Parameters Value
Test Command
AT+HTTPPARA
=?
Response
+HTTPPARA: "HTTPParamTag","HTTPParmValue"
Parameters
See Write Command
Read Command
AT+HTTPPARA
?
Response
+HTTPPARA:
<HTTPParamTag>,<HTTPParamValue>
OK
Parameters
See Write Command
Write Command
AT+HTTPPARA
=<HTTPParamT
ag>,<HTTPPara
mValue>
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<HTTPParamTag>
"CID"
"URL"
HTTP Parameter
(Mandatory Parameter) Bearer profile identifier