Max Response
Time
2s
Reference Note
5.2.3 AT+CFGRI Indicate RI When Using URC
Test Command
AT+CFGRI=?
Response
+CFGRI: (0-2)
OK
Parameters
See Write Command
Read Command
AT+CFGRI?
Response
+CFGRI: <status>
OK
Parameters
See Write Command
Write Command
AT+CFGRI=<st
atus>
Response
OK
ERROR
Parameters
<status> 0 Off
1 On(TCPIP, FTP and URC control RI pin)
2 On(only TCPIP control RI pin)
Parameter Saving
Mode
-
Max Response
Time
-
Reference Note
RI pin can not controll by "AT+CFGRI" command when module has
call service or receiving SMS.
5.2.4 AT+CLTS Get Local Timestamp
AT+CLTS Get Local Timestamp
Test Command
AT+CLTS=?
Response
+CLTS: "yy/MM/dd,hh:mm:ss+/-zz"
OK