SIM7000 Series_AT Command Manual_V1.03 99 2018-05-08
"LTE NB-IOT"
<Operation Mode> UE operation mode.
"Online",
"Offline",
"Factory Test Mode",
"Reset",
"Low Power Mode".
<MCC> Mobile Country Code (first part of the PLMN code)
<MNC> Mobile Network Code (second part of the PLMN code)
<LAC> Location Area Code (hexadecimal digits)
<Cell ID> Service-cell Identify
<Absolute RF Ch Num> AFRCN for service-cell.
<Track LO Adjust> Track LO Adjust
<C1> Coefficient for base station selection
<C2> Coefficient for Cell re-selection
<TAC> Tracing Area Code
<SCellID> Serving Cell ID
<PCellID> Physical Cell ID
<Frequency Band> Frequency Band of active set
<earfcn> E-UTRA absolute radio frequency channel number for s
earching CAT-M or NB-IOT cells
<dlbw>
Transmission bandwidth configuration of the serving cell
on the downlink
<ulbw> Transmission bandwidth configuration of the serving cel
l on the uplink
<RSRP> Current reference signal received power.Available for C
AT-M or NB-IOT.
<RSRQ> Current reference signal receive quality as measured by L
1.
<RSSI> Current Received signal strength indicator
<RSSNR> Average reference signal signal-to-noise ratio of the servi
ng cell The value of SINR can be calculated according to <RSSNR>,
the formula is as below:
SINR = 2 * <RSSNR> - 20
The range of SINR is from -20 to 30