Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 115 2018-05-08
Write Command
<cid>[,<cid>[,…]
]
Response
+CGPADDR: <cid>,<PDP_addr>
[<CR><LF>+CGPADDR: <cid>,<PDP_addr>[…]]
OK
or
Parameters
<cid> A numeric parameter which specifies a particular PDP context
definition (see +CGDCONT Command)
1…24
<PDP_addr> String type, IP address
Format: "<n>.<n>.<n>.<n>" where <n>=0..255
A string parameter that identifies the MT in the address space
applicable to the PDP.
A string parameter that identifies the MT in the address space
applicable to the PDP when the sim_card supports ipv6.
The pdp type must be set to "ipv6" or "ipv4v6" by the
AT+CGDCONT command.
Execution
Command
AT+CGPADDR
Response
[+CGPADDR: <cid>,<PDP_addr>] +CGPADDR:
<cid>,<PDP_addr>[...]]]
OK
If error is related to ME functionality:
+CME ERROR: <err>
If SIM card supports IPV4V6 type and the PDP_type of the command
"AT+CGDCONT" defined is ipv4v6 :
[+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6>]
+CGPADDR: <cid>,<PDP_addr_IPV4>,<PDP_addr_IPV6> [...]]]
See Write Command
Mode
NO_SAVE
Time
-