SIM7000 Series_AT Command Manual_V1.03 146 2018-05-08
OK
Parameters
See Write Command
Read Command
AT+CIPRXGET
?
Response
+CIPRXGET: <mode>
OK
Parameters
See Write Command
Write Command
1) If single IP
connection
(+CIPMUX=0)
AT+CIPRXGET
=<mode>[,<reqle
ngth>]
2) If
multi IP
connection
(+CIPMUX=1)
AT+CIPRXGET
=<mode>[,<id>,<
reqlength>]
Response
OK
ERROR
1)For single IP connection
If "AT+CIPSRIP=1" is set, IP address and port are contained.
if <mode>=1
+CIPRXGET: 1[,<IP ADDRESS>:<PORT>]
if <mode>=2
+CIPRXGET: 2,<reqlength>,<cnflength>[,<IP ADDRESS>:<PORT>]
1234567890…
OK
if <mode>=3
+CIPRXGET: 3,<reqlength>,<cnflength>[,<IP ADDRESS>:<PORT>]
5151…
OK
if <mode>=4
+CIPRXGET: 4,<cnflength>
OK
2)For multi IP connection
If "AT+CIPSRIP=1" is set, IP address and port is contained.
if <mode>=1
+CIPRXGET: 1[,<id>,<IP ADDRESS>:<PORT>]
if <mode>=2
+CIPRXGET: 2,<id>,<reqlength>,<cnflength>[,<IP
ADDRESS>:<PORT>]
1234567890…
OK
if <mode>=3
+CIPRXGET: 3,<id>,<reqlength>,<cnflength>[,<IP
ADDRESS>:<PORT>]
5151…
OK