EasyManuals Logo

SimCom SIM7000 Series At Command Manual

SimCom SIM7000 Series
250 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #160 background imageLoading...
Page #160 background image
Smart Machine Smart Decision
SIM7000 Series_AT Command Manual_V1.03 160 2018-05-08
Test Command
AT+HTTPTOFS=
?
Response
+HTTPTOFS: (1-255),(1-127)
OK
Read Command
AT+HTTPTOFS?
Response
+HTTPTOFS: <status>,<url>,<file_path>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
See Write Command
Write Command
AT+HTTPTOFS=
<url>,<file_path>
Response
OK
+HTTPTOFS: <StatusCode>,<DataLen>
Parameters
<status>
0 Idle
1 Busy
<url> The url
<file_path>
File path and name on ap side,
For example: "/customer/test.bin","/custapp/ test.bin
","/fota/test.bin"
<StatusCode>
HTTP Status Code responded by remote server, it
identifier refer to HTTP1.1(RFC2616)
100 Continue
200 OK
206 Partial Content
400 Bad Request
404 Not Found
408 Request Time-out
500 Internal Server Error
600 Not HTTP PDU
601 Network Error
602 No memory
603 DNS Error
604 Stack Busy
620 SSL continue
65535 Other Errors
<DataLen>
The length of data download
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals