SIM7000 Series_AT Command Manual_V1.03 233 2018-05-08
OK
If no <cid> has been set by AT+CACID:
OK
Parameter
See Write Command
Write Command
AT+CAOPEN=<ci
d>,<server>,<port
>
Response
+CAOPEN: <cid>,<result>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<cid> see AT+CACID
<server> Alphanumeric ASCII text string up to 64 characters
. Server IP
address or host name.
<port> Interger. Server port.
<result>
0 Success
1 Status error
2 Configure type error
3 Parameter invalid
4 TCP connect error
5 UDP create error
6 Configuration load error
7 Socket add error
8 Certificate’s time expired
9 Certificate’s common name does not match
10 Certificate’s common name does not match and time expired
11 Connect failed error
12 Socket handle error
13 Data length error
14 Memory error
15 Data send error
16 SSL general error
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference
Note
SIMCOM COMFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM7000 Series and is the answer not in the manual?

SimCom SIM7000 Series Specifications

General IconGeneral
BrandSimCom
ModelSIM7000 Series
CategoryControl Unit
LanguageEnglish

Related product manuals