User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
in
Set point value
parameter write
50
,
for
Displaying
block parameters:
Format
parameter set as
numeric
,
Precision
parameter set as
0
,
in
Graph low
write
0
,
in
Graph high
write
50
,
Other logical channels set the same way:
logical channel 5: Name 5, Set point value: 30,
logical channel 8: Name 8, Set point value: 80,
logical channel 12: Name 12, Set point value: 5,
For Logical channel in
Math function
mode:
using the arrows in the top navigation bar, select
logical channel 1
,
in
Name
parameter write
Function
,
Mode
parameter set as
Math function
,
enter
Function
submenu to select the appropriate function that allows the
calculation of the mean value,
Function parameter set as
X[i] selected by Y
,
in
Source X
parameter select
logical channels: 1
,
5
,
8, 12
, which we defined
as a constant values,
in
Source Y
parameter select
logical channel 2
,
for
Displaying
block parameters:
Format
parameter set as
numeric
,
Precision
parameter set as
0
,
in
Graph low
parameter write
0
,
in
Graph high
parameter write
80
,
130