User Manual For - CONTROLLER/DATA RECORDER MultiCon CMC-99/141
press the sign
'+'
and then:
Output active
parameter set as
yes
,
Control type
parameter set as
as a relay
,
in
Output register
submenu:
in
Register number
parameter write
8h
,
Data format
parameter set as
16 bits, unsigned
(this depends on
register format in Slave device),
in
Data mask
parameter write
0x0001
,
in
Data shift
parameter write
0
,
Blocks config.mode
parameter set as
manual
,
in
Block list
submenu:
Block type
parameters set as
write HOLDING reg.
,
Register size
parameter set as
16-bit registers
(according to registers
format in Slave device),
in
First register
parameter write
1h
,
in
Last register
parameter write
2h
,
create next block by pressing
'+'
sign,
Block type
parameter set as
write HOLDING reg.
,
Register size
parameter set as
16-bit registers
(according to registers
format in Slave device),
in
First register
parameter write
4h
,
in
Last register
parameter write
4h
,
create next block by pressing
'+'
sign,
Block type
parameters set as
write HOLDING reg.
,
Register size
parameter set as
16-bit registers
(according to registers
format in Slave device),
in
First register
parameter write
8h
,
in
Last register
parameter write
8h
,
move to the
Device templates
parameter block and press
Save device template
button,
in the
Save device template
menu, enter the template name, eg
Write do device
(stored template can be used to configure the device to a
different address),
222