11. System configuration
System configuration
Step Key Display Description
System configuration - Amount of pumps, Pump settings, Set Params to Default
- only in Supervisor password level
1
)Requirement: Supervisor password
level is enabled.
• Use <down/up arrow key> to select
System configuration.
• Press <OK control key>
)You will enter the System configuration
menu.
)You will be asked "Lubrication will be
stopped - Continue?"
• Press <Yes control key>
)You will enter the System configuration
menu. The following settings can be
made:
o Amount of pumps- see Chapter 11.4
o Configuration of pumps
see Chapter 11.5
o Set Params to Default /
Condition on Delivery
see Chapter 11.7
Main menu
Login settings
User settings
Device settings
Pump 1 Timings
System configuration
Information
System configuration
Lubrication will be stopped
Continue?
Yes
No
System configuration
Amount of pumps
Setting the pump
Set Params to Default
Condition on delivery
IMPORTANT NOTE
SKF Service menu
This level is password-protected and can-
not be accessed from the operator level or
the Local Admin level.
Settings can be made only in the
Supervisor password level.
All essential controller and system settings
for an SKF Dual Line Dual Line centralized
lubrication system are made in the System
configuration menu level.
These settings can and may only be made
by SKF Service.
11.3 Menu structure for system configuration
Supervisor password
factory setting: 2020
SelectBack
Back
Ok
EN
104