8. Maintenance
8.1 General information
8. Maintenance
SKF products are low-maintenance.
The following work/inspections should be
performed to ensure proper function:
o The button cell battery attached to the in-
side of the controller lid must be replaced
before its expiration after 24 months -
see Chapter 8.3.
The interior of the controller is not de-
signed to be cleaned. Cleaning of the inte-
rior using liquids is prohibited!
A 3-amp blade-type fuse protects against
overload. Replace the fuse once it has actu-
ated - see Chapter 9.1.
Contact the SKF Service department in case
of problems with the LMC 301 controller
unit.
IMPORTANT NOTE
Only original SKF spare parts may be used.
Unauthorized alterations and the use of
non-original spare parts and accessories
are prohibited and nullify the statutory
warranty.
Dismantling of the product or individual
parts of the product within the statutory
warranty period is prohibited and voids any
claims.
IMPORTANT NOTE
The LMC 301 Controller contains
electronic components that can be
destroyed by accidental electro-
static charge or discharge (ESD).
To prevent possible damage due
to ESD, hands and any tools must
be discharged on a bare grounded
position on the installation site prior
to performing any work in the area
of the opened control unit’s circuit
board. Conductors or component
connections within the device
must not be touched under any
circumstances
EN
WARNING
Electric shock
De-energize the controller prior
to beginning work.
Only qualified personnel autho-
rized by the operator may perform
work on the controller.
The electrical operating conditions
and local regulations (e.g., DIN,
VDE) must be observed.
78