Fault notification Cause Remedy
Empty signal
o Grease reservoir
empty
Fill grease reservoir
No pressure build-up at
pump pressure switch
o Line broken
Inspect lubrication system, replace broken lubrication line if necessary
o Pump motor is
defective
Replace the pump
o Sensor is defective
Replace the sensor
No pressure build-up at
reversing valve
o Blockage of pressure
switch
o Signal line is broken
o Monitoring time
exceeded
Check pressure switch for proper function, replace if necessary
Check signal line for damage, replace if necessary
Adjust the monitoring time
o Sensor is defective
Replace the sensor