9. Malfunctions, causes, and remedies
EN
89
9
Malfunction Cause Remedy
No pressure build up in
the main line
o Air in the main line
o Main line leaky or break in line
Vent main line
Repair main line
o Pressure-regulating valve does not
close
Check pressure-regulating valve to make sure that opening
pressure is correct and that there is no contamination or damage
If opening pressure is incorrect or if the pressure-regulating valve
is damaged, replace the valve Only use original SKF spare parts.
If contaminated, clean the pressure-regulating valve
No pressure build up in
the main line
o Reversing valve does not close
Clean or replace reversing valve.
Only use original SKF spare parts.
o Unsuitable lubricant
(see “Technical Data,” Chapter 3)
Remove lubricant from entire system and dispose of lubricant in
the proper manner; fill system with suitable lubricant
o Fill level too low
Top up lubricant
o Feeder clogged
o Air in the lubrication system
Clean feeder/injector nozzle
Vent the lubrication system