EasyManua.ls Logo

SKF LMC 301 series - System Malfunctions

SKF LMC 301 series
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9. Malfunctions, causes, and remedies
EN
87
9
9.5 System malfunctions
Malfunction Cause Remedy
Motor fails to start
when the operating
voltage is applied
o No operating voltage on motor
o Phase absent
Check mains connection
Check mains plug/cable and connect properly if necessary
Check operating voltage on motor
Check fuse
Check motor circuit breaker
o Pump jammed
Measure motor current If current is impermissibly high:
Dismantle pump, crank by hand:
if resistance is high, replace the pump.
o Motor jammed
Measure motor current If current is impermissibly high:
Dismantle motor, crank by hand:
If resistance is high, replace the motor.
Pump motor runs
with difficulty and
at a low speed
o Sluggish pump
Measure motor current If current is impermissibly high:
Dismantle pump, crank by hand:
if resistance is high, replace the pump.
Motor runs with
difficulty and at a
low speed
o Sluggish motor
Measure motor current If current is impermissibly high:
Dismantle motor, crank by hand:
If resistance is high, replace the motor.
o Unsuitable lubricant
(see “Technical Data,” Chapter 3)
Remove lubricant from entire system and dispose of lubricant in
the proper manner; fill system with suitable lubricant
o Pressure too high, pressure-regulating
valve is jammed or defective
Check pressure-regulating valve and replace if necessary

Table of Contents

Other manuals for SKF LMC 301 series

Related product manuals