EasyManuals Logo

SKF LMC 301 series User Manual

SKF LMC 301 series
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #82 background imageLoading...
Page #82 background image
9. Malfunctions, causes, and remedies
EN
82
Fault display, Table 2
Display Fault status Fault output Cause
FAULT LED is off No error
ERROR LED flash-
ing red
Pump1/Zone1 = A
Pump1/Zone2 = B
Pump1/Zone3 = C
Error has occurred in the indicated area.
Read error notification on display.
Error LED is on Fault Hardware error
9.2 Display of fault notifications via fault LED
9.3 Display of fault notifications on the screen
Code Fault notification Fault
[001] Pump/Zone Config Pump zone configuration not valid
[002] Pump Sens. Offline Input sensor at pump not available
[003] Pump Sensor Config Input sensor at pump: wrong settings
[004] Pump Sens. Address Input sensor at pump: address multiple
[005] Pump Sensor Fault Input sensor at pump sensor: value too high
[006] Pump Sensor NC Input sensor at pump: Open Loop detected
[007] Remote Offline Input remote: not available
[008] Remote Config Input remote: wrong settings
[009] Remote Address Input remote: address multiple

Table of Contents

Other manuals for SKF LMC 301 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF LMC 301 series and is the answer not in the manual?

SKF LMC 301 series Specifications

General IconGeneral
BrandSKF
ModelLMC 301 series
CategoryController
LanguageEnglish

Related product manuals