11. System configuration
Lube Control => Press. Sensor at EOL
Step Key Display Description
Zone 1 Settings/Lube Control Zone 1 Pressure sensor at end of line (EOL)
1.3
With sensor selection as normally closed or normally open:
Use <down/up arrow key> to select the sensor type normally closed or normally open
Press <Save control key>
Use <down arrow key> to select the Input menu item
Press <Select control key>
Use <right/left arrow key> to enter the input No.
Press <Save control key>
Press <Back control key>
With sensor selection as transducer (see p. 41 for functional description of transducer):
Use <down/up arrow key> to select the sensor type transducer
Press <Save control key>
Use <down arrow key> to select the Input A menu item
Press <Select control key>
Use <right/left arrow key> to enter the Input No.
Press <Save control key>
Repeat entry for Input B
Press. Sensor at EOL
Sensor Type
[normally open]
Input
[1.01.] AI
Select
Back
Press. Sensor at EOL
Sensor Type
[ << transducer 1-6V >>
<< transducer 4-20 mA >>
<<transducer 0-20mA >>
<<transducer 2-10V >>
<<transducer 0-10V>>
<< normally closed >>
<< normally open >>
<<disabled>> ]
Input A
[ 1.02 ] AI
Settings Settings with 3/2 directional control valves
Select
Back
EN
129
11

Table of Contents