3. Technical data
EN
26
Characteristics, design
Output rating of relays
Connection directly to relay 01/02 100-240 VAC/max. 15A
Connection directly to relay 01/02 24 VDC/max. 15A
Output terminal strip 01 to 08 24 VDC; 100-240 VAC/max. 8A
Note: Do not operate two different operating voltages (AC and DC)
within the same terminal strip!
Safety DIN EN 60204-1
Safety class Class I
Connection cables provided by customer
Temperature stability >70°C
EMC
Interference suppression VDE 0875 T 11, DIN EN 55011 Class A
Emitted interference acc. to DIN EN 61000-6-3
Immunity acc. to DIN EN 61000-6-2
Note: The emitted interference meets the requirements for industrial
use; use in a residential area may cause interference under
some circumstances.
Characteristics, design
LMC 301 Versions Order No.
24 VDC 086500
100 to 240 VAC 086501
24 VDC I/O 086502
100 to 240 VAC I/O 086503