102
5 - Subsequent system control delay
This parameter is useful to manage machine operation when it is inserted in an automatic line.
It is a signal which is transmitted to the machine by an external device. For example if the
wrapping machine were connected to the heat-shrinking tunnel and this should break down, a
signal would be sent automatically and the wrapping machine would stop, only to restart after
the problem was resolved.
The following page carries the structure of the FORMAT PARAMETERS only.
The operator is recommended to print this summary menu and to use it to take note of the
values of the parameter set for each format memorised.
Fig. 9.17.6
0 = parameter disabled
FLOW
Esc
Mod
RUNNING SUBSEQUENT
SYSTEM CONTROL DELAY
[s]
0