97
The following menus below (LOCAL BUSES, DIO 16 INPUT OUTPUT, CUS A1, INVERTER
MODULES) contain information and technical data on the status of the electronic modules
installed inside the electrical panel. This data can be used to determine the cause for machine
failure linked to errors on the electronic modules. For more information, refer to the specific
DM200125 manual that come with it.
9.16 Utility menu
The "Utility" menu allows you to perform the operations described here below.
>Set LCD
Press and then and go through the menus:
1 - Choosing display language
Menu for the setting of the language.
2 - Locking format parameters
If you set YES, the parameters can be modified exclusively in the menu PROGR; after exiting
this menu, the values can not be modified any longer, but can only be displayed. The standard
setting is NO, which means that the parameters modification is always possible.
Fig. 9.16.1
Fig. 9.16.2
SET LCD
DISPLAY
LANGUAGE
Esc
Mod
ENGLISH
SET LCD
FORMAT PARAMETERS
BLOCK
Esc
Mod
NO