S10.7.3 ADJUSTING THE SENSORS OF THE SEALING BAR
MACHINE STATUS: machine in stop
FREQUENCY: in case of interventions on the sealing bar which require their adjustment
REQUIRED MATERIAL: wrench CH8,17 and screwdriver.
PROCEDURE:
Disconnect the cable coming out of the top frame and then adjust the horizontal position and height
of the sealing bar sensors (16), observing the instructions set forth in the figure.
When the adjustment has been made, reconnect the cable of each sensor.