Notifications
The output measured from the inverters is contrasted with the generator capacity that is listed in the sys-
tem.
A notification is sent (by email) when the deviation exceeds the amount configured (for example 10%) over
a set time period (for example 30 minutes).
Note!
For performance monitoring configurations, see the chapter "Configuring Notifi-
cations
" in the Installation Manual.
3.2.1 Performance Monitoring Notification
Example Notification:
Module Field 1 - Inverter 1 'Inverter 1 House'
IRV = 4916W ( Inverter 2, Inverter 2 House' ), IAV = 3950W, deviation = 19.65 %
The notification contains the following information:
Module field:
The module field which was affected or at least the module field in which a deviation was detected.
Deviating inverter:
Inverter 1
IRV:
The reference value that is used to contrast inverters. It comes from the most effective operating inverter,
the value is in W.
IAV:
The amount of output from inverter with a deviation.
Dev:
The amount of deviation as a percentage of the reference value.

Table of Contents

Other manuals for Solar-Log 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solar-Log 2000 and is the answer not in the manual?

Solar-Log 2000 Specifications

General IconGeneral
Device TypeData Logger
Max Inverters100
Power Supply24 V DC
Remote MonitoringYes
Ethernet interfaceYes
Communication InterfacesRS485, Ethernet
ProtocolsModbus
Data StorageInternal

Related product manuals