Spectra Precision Focus 6 5" Total Station User Guide 101
Applications 4
Sample output records through COM port
When the Ext.Comm field is set to NIKON:
TR PN: PT8 SD:000066626 HA:003856010 VA:008048500 HT:0000061757
(TR PN: point name SD HA VA HT; when ACK is returned, PN is incremented.)
When the Ext.Comm field is set to SET:
0006662 0804806 0394324 97
(SD VA HA Chk-SUM)
Measuring Offsets
Measuring taped offsets
1. To enter the taped offset function, press [1] or select
Tape in the Offset menu.
If you have not taken a distance measurement
before entering this function, a temporary
measurement screen appears.
2. Sight the target and press
[MSR1] or [MSR2].
3. Enter offset distances from the measured point.
Use
[^] or [v] to move to the appropriate offset field.
Left (-)
In (-)
Up (+)
Out (+)
Down (-)
Right (+)