Spectra Precision Focus 6 5" Total Station User Guide 121
Menu Key 5
B
Tip – When you download data in Nikon RAW format, area (AR) records are output as
comment (CO) records.
Advanced feature: Entering a range of points
To quickly enter a sequential range of points, use the
range input function. To access this function, press the
Fr/To softkey in the No. 01 or No. 02 input screens.
Enter the start point name in the Fr field and the end
point name in the To field. You can include letters and
hyphens in the point names, but the last character must
be numeric.
Press
[ENT] in To field to start searching for matching
points. The counter shows the number of matching
points found.
When the search is complete, you are returned to the
Input PT screen.
Press the
Calc softkey to calculate the area and
perimeter, or enter point names in the PT field.
Press
[ESC] to return to the Input PT screen with the
preceding point name.