Spectra Precision Focus 6 5" Total Station User Guide 141
Menu Key 5
Editing station records
Note – The system will not recalculate measurements if you change the station record. All
coordinate and raw data observed from an edited station record must be recalculated in
your postprocessing software.
In the RAW screen, use
[^] or [v] to highlight the station
record that you want to edit. Then press the
Edit
softkey.
You can edit any field in the ST record, but the
instrument does not recalculate any measurements
from this station.
Press
[ENT] in the AZ field to confirm the change.
B
Tip – If you change the ST or HI values, the coordinates of
observation points are not recalculated. A comment record is stored to record the change.
The following example shows a comment record for a changed HI value:
CO,HI changed at ST:9012 Old HI= 1.345m
If you change the BS or AZ values, raw records are not recalculated. A comment record is
stored to record the change.