Spectra Precision Focus 6 5" Total Station User Guide 75
Applications 4
1. To start the resection, press [2] or select
Resection in the Stn Setup menu.
2. Enter the point name for the first observation
point (PT1).
3. Enter the target height and press
[ENT].
4. Sight PT1 and press
[MSR1] or [MSR2].
5. To proceed to the next point, press
[ENT].
6. Enter the second point (PT2) and its height of
target.
7. Measure to PT2 and press
[ENT].
When the instrument has enough data, it
calculates the station (STN) coordinates.
– If more than the minimum required data is
available, a standard deviation screen
appears.
– To take measurements to strengthen
geometry of the resection, press the
Add
softkey. For information about the
View
softkey, see Advanced feature: Viewing and deleting a measurement in
resection, page 76.