Machine maintenance and care
11.5.5 On-board hydraulic system for hydraulic functions or for blower drive
In case of the on-board hydraulic system:
check the oil level and top up hydraulic oil, if necessary,
change the hydraulic oil / replace the filter element.
ο but at least every 2 years (depending on which change
interval occurs first).
Required hydraulic oil, on-board hydraulic system for hydraulic
functions:
ο Hydraulic oil ATX 40 (similar to ATF oil),
Change the hydraulic oil:
ο for the first time after 500 service hours,
ο then every 3000 service hours,
ο Filling capacity approx. 21 litres.
Required hydraulic oil, on-board hydraulic system for blower
drive:
Never mix different types of hydraulic oil
Dispose of used oil according to regulations. Should you have
any problems with disposal, consult your oil supplier!
Replace the filter element:
ο for the first time after 250 service hours,
ο then every 2000 service hours,
ο but at least every 2 years (depending on which change
interval occurs first).
ο Hydraulic oil ATX 40 (similar to ATF oil),
ο Filling capacity approx. 52 litres.
1
The oil level must be visible at the
inspection glass.
2
Fig. 87
11.5.5.1 Check oil level
. Check the oil level at the inspection glass
(1).
. Fill hydraulic oil through the filler neck (2)
into the hydraulic oil tank, if necessary.