Scale System Operation Guide
25
SCALE SYSTEM CONTROL PANEL GUIDE (OPTIONAL EQUIPMENT)
1. LCD displays patient weight. Trendelenburg angle is displayed when the scale is not active.
2. Press to zero bed (page 26). Also press to scroll while Menu Mode is active.
3. Press to enter and exit the Menu Mode.
4. Press when adding or removing equipment to the bed (page 27).
5. Press to turn scale system on and off. Also press to scroll while Menu Mode is active.
6. Press to change weight from pounds to kilograms or back (page 28). Also press while using the Menu Mode.
NOTE
If weight is displayed, SCALE ON/OFF must be pressed to turn off the scale before the Trend. or Fowler angle
will display.
CAUTION
Scale function may be affected by siderail/caster interference. With the litter fully lowered or lowered in Re-
verse Trendelenburg, the siderails tucked under the litter in the storage position and the casters turned, there
is the potential for interference between the siderail and the caster. Raise the siderails when lowering the
litter to the full down position to prevent the interference from causing the scale system to weigh inaccurately.
WARNING
To avoid possible injury and to assure proper operation when using a powered mattress replacement system
such as XPRT:
Confirm proper scale system operation following mattress installation. For best results, secure the mat-
tress power cord to prevent damage to the cord and interference with the bed frame and the scale system.
Do not zero bed scales or weigh patient with Percussion, Vibration, Rotation or TurnAssist active. Patient mo-
tion and position resulting from the dynamic therapy mattress may adversely affect scale system performance.
For more detailed operating instructions, see the following:
1. Preparing The Bed For Patient Stay/Zeroing the Bed page 26
2. Activating the Scale System and Displaying Patient Weight page 26
3. Adding or Removing Items During a Patient’s Stay page 27
4. Converting the Patient’s Weight page 28
5. Displaying the Weight Log page 29
6. Viewing Patient Weight In Gain/Loss Mode page 30
7. Changing the Numerical Value Of Displayed Weight page 31

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stryker Secure II 3002 and is the answer not in the manual?

Stryker Secure II 3002 Specifications

General IconGeneral
BrandStryker
ModelSecure II 3002
CategoryMedical Equipment
LanguageEnglish

Related product manuals