56
6-9) Set the Back-Tack function
① Check that the sewing READY lamp if off, and press the
DOWN key six times. It makes DATAINFO blink. Press
ENTER and then the initial parameter setup screen appears.
② On the initial parameter setup screen, use the UP or DOWN
key and select ‘8:BT_STI’. Press ENTER.
③ A new screen pops up and ‘1’ blinks. Use the UP or DOWN
key to select ‘1’ and press ENTER to set the starting back-tack
value.
④ Use ◀(+) and ▶(-) to select the desired value and press
ENTER. Then the O.K.! message is displayed on the screen.
(setting range: 0 ~ 2)
⑤ The screen moves back to the previous one and ‘1’ blinks
again. Select ‘2’ and follow the same process as above to set
the ending back-tack value.
⑥ When trying to end the back-tack setting, use the DOWN key
to select [RETURN] and press ENTER.
OR
↓
OR
↓
↓
↓
↓