SunStar SPS/E-BH6100 - Compensation of Eyelet Part; Adjusting Eyelet Rotation and Radius

SunStar SPS/E-BH6100
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
6-5) Compensation of the eyelet part
Check that the READY lamp is off, and press the DOWN key
five times. Then DATAINFO flickers. Press ENTER and the
initial parameter setting screen appears.
Select ‘4: E_Comp.’ by using the UP or DOWN key and press
ENTER.
A new screen pops up, and ‘1’ blinks. Select ‘1’ by using the UP
or DOWN key to compensate rotation value and press ENTER.
When a new screen shows up, set the desired value by using
(+) and (-), and press ENTER. Then the O.K.! message is
displayed on the screen.
+ direction: The eyelet angle increases by the set value.
- direction: The eyelet angle decreases by the set value.
The screen returns to the previous screen and ‘1’ blinks. Select
‘2’ by using the UP or DOWN key to compensate the radius
value, and press ENTER.
When a new screen appears, set the desired value using (+)
and
(-), and press ENTER. Then the O.K.! message is
displayed on the screen.
+ direction: The radius of eyelet increases by the set value.
- direction: The radius of eyelet decrease by the set value.
On a new screen, 2blinks. Select 3using UP or DOWN
to compensate the X-direction location, and press ENTER.
When the value setting screen appears, select the desired value
using (+) and (-) and press ENTER. The O.K.! message is
displayed.
+ direction : The X-direction location of eyelet is moved to the
right side.
- direction : The X-direction location of eyelet is moved to the
left side.