46
6-5) Compensation of the eyelet part
① Check that the READY lamp is off, and press the DOWN key
five times. Then DATAINFO flickers. Press ENTER and the
initial parameter setting screen appears.
② Select ‘4: E_Comp.’ by using the UP or DOWN key and press
ENTER.
③ A new screen pops up, and ‘1’ blinks. Select ‘1’ by using the UP
or DOWN key to compensate rotation value and press ENTER.
④ When a new screen shows up, set the desired value by using
◀(+) and ▶(-), and press ENTER. Then the O.K.! message is
displayed on the screen.
+ direction: The eyelet angle increases by the set value.
- direction: The eyelet angle decreases by the set value.
⑤ The screen returns to the previous screen and ‘1’ blinks. Select
‘2’ by using the UP or DOWN key to compensate the radius
value, and press ENTER.
⑥ When a new screen appears, set the desired value using ◀(+)
and
▶(-), and press ENTER. Then the O.K.! message is
displayed on the screen.
+ direction: The radius of eyelet increases by the set value.
- direction: The radius of eyelet decrease by the set value.
⑦ On a new screen, ‘2’blinks. Select ‘3’using UP or DOWN
to compensate the X-direction location, and press ENTER.
⑧ When the value setting screen appears, select the desired value
using ◀(+) and ▶(-) and press ENTER. The O.K.! message is
displayed.
+ direction : The X-direction location of eyelet is moved to the
right side.
- direction : The X-direction location of eyelet is moved to the
left side.
↓
OR
↓
↓
OR
↓
OR
↓
↓
↓
↓
OR
↓
OR
↓
↓
↓
↓