74
99
Parameter Changing Methods and Classification
9-1) Parameter numbers related to general sewing (Group A)
★ Turn on the power, while pressing the left key and the presser UP/DOWN key at the same time, and then ‘1’ flickers on the screen. Press
ENTER, and the screen shows the item list of parameter Group A. Use the DOWN key to select the desired number and press ENTER.
Then, the parameter setting screen appears. Use the + and - key to change the parameter values. Press ENTER to save the changed values.
No Function and Description
Name of Function
Setting Range Default Unit
A-01
Maximum sewing speed m spm 2500 spm 2200 spm 100spm
A-02
Set the sewing starting speed for 1st~5th
needle (set the soft start)
Slow
1st needle :
100~900
2st needle
:100~2700
3st needle
:100~2700
4st needle
:100~2700
5st needle
:100~2700
200spm
500spm
1000spm
1500spm
2500spm
100spm
A-03
Set the X-Y transfer position F pos -100 ~+100 0 1
A-04
Set the thread trimming speed T spm 200~400 spm 400 spm 100spm
A-05
Set the UP/DOWN production counter CntMd
Down Product
Up Product
Up Product
A-06
Set the production counter
CntFg
Disable
Enable
Disable
A-07
Set the down mode
CntDn
Buzz & Key
Key
Buzz
Buzz & Key
A-08
Origin check mode setting
M_ORG
Counter:Origin after countering
completes
Auto:Origin after sewing scompletes
Counter
A-09
Origin check counter setting C_ORGv 0 ~ 256 20 1
A-10
Set the automatic check of rocking point LIM_S
Disable
Enable
Enable
A-11
When start sewing, thread tension solenoid
on time setting
SoITM 4~1020ms 100ms 4ms
A-12
When sewing is stopped, set the value of thread tension
(Use the upper thread holder)
N_off 5~100 30 1
A-13
Enable/Disable of upper thread nipper
device
NIP_D
Disable
Enable
Enable
A-14
Thread tension solenoid Full-on time setting THSOL 4~1020ms 100ms 4ms
A-15
Feeding base position setting BaseP
Origin Position
Sewing Position
Origin
Position
A-16
Deciding the use of the vent_hole pattern HOLE
Disable
Enable
Disable
A-17
When sewing is stopped, set the value of thread tension
(Use the upper thread holder)
N_On 10~200 150 1
A-18
AC Off time setting ACOff 4 ~60ms 20ms 4ms
A-19
Overvoltage check time setting OverL 4 ~1020ms 20ms 4ms
A-20
When power switch is in the "ON" position, set the
initial value of thread tension
ITens 10 ~60 20 1
A-21
When moving the feed base to the sewing position to set the
second origin, set the operation of the fabric opening device
.
OPEN
Enabled
Disabled
Disable
A-22
Hand switch mode setting PMode one switch dual switch dual switch
A-23
Setting the time taken from presser foot
descent to beginning of sewing
PF_TM 4 ~ 1020ms 100ms 4ms
A-24
Feed base speed adjustment (Advance)
YFeed 4 ~ 1020ms 16us 4us
A-25
Blade motion method choice (Sensor or Timing)
KMode
Sensor or Timing
Sensor
A-26
Low voltage error check frequency setting UndrL 4 ~ 1020ms 20ms 4ms
A-27
Set thread breakage check though sewing ThCut
Disable
Enable
Disable
A-28
Set thread breakage stich numbers ThSti 6~30[stitch] 10[stitch] 2[stitch]
A-29
Feed base speed control(reverse) BWspd 1~50[us] 15[us] 1[us]
A-30
Delayed time to complete the knife operation KnfTM 4~1020[ms] 100[ms] 4[ms]
A-31
Set thread breakage stich numbers UT_TM 4~1020[ms] 100[ms] 4[ms]
A-32
Evaluate and set up the angle of separating thread
from the lower thread during lower thread trimming.
UtAng 1 ~ 180[degree] 15[degree] 1[degree]
A-33
Set up the location of clamp after finish stitching.
(in case of thread detection and emergent stop)
ST_PF down / up down
A-34
After finish stitching set up the thread tension ON time
before upper thread trimming.
On TM 4 ~ 400[ms] 600[ms] 4[ms]
A-35
After finish stitching set up the thread tension OFF time
before upper thread trimming.
Off TM 4 ~ 400[ms] 100[ms] 4[ms]