EasyManua.ls Logo

SunStar SPS/E-BH6100 - 6-11) Use of Upper Thread Nipper Device (Optional)

SunStar SPS/E-BH6100
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
59
6-11) Setting method of upper thread holder device usage
Turn on the power while pressing the LEFT key and the clamp
Up/Down key simultaneously. You can see ‘1’ blink on the
screen. Select Group A and press ENTER to use the upper
thread nipper device.
When a new screen appears, use the DOWN key to select ‘A13
: NIP_D’ and press ENTER.
When a new screen appears, use (+) and (-) to select or
cancel the upper thread nipper device.
Select : Enable
Cancel: Disable
Press ENTER and you can hear a “beep” sound, which
indicates the completion of the setting. The screen returns to
the Parameter A Group screen.
+
OR
+
Power On
upper thread holder device can be used only in the BH6100 -0.1, -0.2 model.
Caution