Linear operating ranges with Airport filter
The starting point at which tests of level linearity shall begin is 94.0 dB for the frequencies specifies below. For
the Low measurement range and A weighting linearity test at 31.5 Hz, the starting point is 79 dB.
Table C.5.4. Linear operating ranges for the Normal measurement range and the Airport filter (for the
sinusoidal signal and microphone sensitivity 32 mV/Pa)
[dB]
L
AS/F
L
BS/F
L
CS/F
L
ZS/F
L
AeqT
L
BeqT
L
CeqT
L
AE
L
Cpeak
(t
int
= 2 s)
from
to
from
to
from
to
from
to
from
to
from
to
from
to
from
to
from
to
31,5 Hz
29
97
29
120
29
134
36
137
29
97
29
120
29
134
32
100
55
137
500 Hz
29
133
29
136
29
137
36
137
29
133
29
136
29
137
32
136
55
140
1 kHz
29
137
29
137
29
137
36
137
29
137
29
137
29
137
32
140
55
140
4 kHz
29
138
29
136
29
136
36
137
29
138
29
136
29
136
32
141
55
139
8 kHz
29
136
29
134
29
134
36
137
29
136
29
134
29
134
32
139
55
137
12.5 kHz
29
132
29
131
29
131
36
137
29
132
29
131
29
131
32
135
55
134
Table C.5.5. Linear operating ranges for the Low measurement range and the Airport filter (for the sinusoidal
signal and microphone sensitivity in the range 32 mV/Pa)
[dB]
L
AS/F
L
BS/F
L
CS/F
L
ZS/F
L
AeqT
L
BeqT
L
CeqT
L
AE
L
Cpeak
(t
int
= 2 s)
from
to
from
to
from
to
from
to
from
to
from
to
From
to
from
to
from
to
31,5
Hz
26
80
26
103
26
117
32
120
26
80
26
103
26
117
29
83
50
120
500 Hz
26
116
26
119
26
120
32
120
26
116
26
119
26
120
29
119
50
123
1 kHz
26
120
26
120
26
120
32
120
26
120
26
120
26
120
29
123
50
123
4 kHz
26
121
26
119
26
119
32
120
26
121
26
119
26
119
29
124
50
123
8 kHz
26
119
26
117
26
117
32
120
26
119
26
117
26
117
29
123
50
120
12.5 kHz
26
115
26
114
26
114
32
120
26
115
26
114
26
114
29
118
50
117
Table C.5.6. Self-generated noise for different weighting filters
Electrical *)
Acoustical compensated
Weighting filter
Range
A
C
Z
A
C
Z
Low
< 15 dB
< 14 dB
< 20 dB
< 16 dB
< 16 dB
< 22 dB
Normal
< 26 dB
< 25 dB
< 32 dB
< 26 dB
< 26 dB
< 32 dB
*) measured with the ST 03 microphone equivalent impedance 18 pF +/-10%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Svantek SV 971A and is the answer not in the manual?

Svantek SV 971A Specifications

General IconGeneral
BrandSvantek
ModelSV 971A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals