SYNCHRO Excite +: Service & maintenance manual - rev. 7.1
Page 9.16
9.3.3.3. Default Setting
To load the default parameter values, scroll using the +/- effort level keys until the display shows:
DEFAULT SETTING ?
Press ENTER. Display shows:
CONFIRM ?
Press ENTER to write the default values to the low kit, and return to the upper menu level by
pressing CLEAR for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.3.3.4. Table of configuration parameters:
Id
(Par.)
Units Name Description
Power factor correction (constant torque)
Maximum temperature on the coil
8
Rpm
]
Minimum user SPM
(start cut braking ramp)
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
11
[Rvel] Speed ratio (decimal part)
User delta friction torque
Enable flag for registers at address ≥ 100