SYNCHRO Excite +: Service & maintenance manual - rev. 7.1
Page 9.16
9.3.3.3. Default Setting
To load the default parameter values, scroll using the +/- effort level keys until the display shows:
DEFAULT SETTING ?
Press ENTER. Display shows:
CONFIRM ?
Press ENTER to write the default values to the low kit, and return to the upper menu level by
pressing CLEAR for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.3.3.4. Table of configuration parameters:
Id
(Par.)
Units Name Description
LED
powered
Self-powered
1
decimal
[Rt]
Transmission Ratio
166
166
2
[Rvel]
Speed ratio
1
1
3
mA
[Im]
Minimum braking
0
0
4
W
[Pmc]
Constant maximum power
200
200
5
in cent
[Km]
Power factor correction (constant torque)
100
100
6
0.1N
[Ca]
User friction torque
23
23
7
°C
[Tea]
Maximum temperature on the coil
125
125
8
User
Rpm
[RPMmin
]
Minimum user SPM
(start cut braking ramp)
35
35
9
Type/sec [RpmF1]
Flywheel target RPM speed in standby
(and power-on speed for self powered)
1
1
10
User Rpm
[RpmF2]
Rpm filter threshold
75
75
11
[Rvel] Speed ratio (decimal part)
60
60
12
0.1N
[D_Ca]
User delta friction torque
6
6
13
-
-
Enable flag for registers at address ≥ 100
-
-