SYNCHRO Excite +: Service & maintenance manual - rev. 7.1
Page 9.20
9.3.5.3. COM.Fault
This is a counter that displays the number of errors in serial communication between the upper and
the lower kit. This counter increase each time a communication fault is detected. Scroll using the +/-
keys until the display shows:
COM.FAULT X
To reset it press ENTER, the LED display shows:
RESET COM.FAULT?
Press ENTER to reset and return to the upper menu level by pressing CLEAR for a few seconds.
9.3.5.4. View Errors
For every error generated by the machine, the error history log records the information in the table
below:
Counter
Error code
Current when the error occurred
Distance in km when the error occurred
The correspondence between error codes and descriptions is given in the table below:
Error Code
Description
1
OVERHEATING: this condition occurs when the temperature detected by the
sensor on the circuit board exceeds 90°C.
8
OVERVOLTAGE: this condition occurs when the +12Vdc voltage goes above
13.7Vdc (only for 700 LED and 700 VISIO).
Use the + effort level key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.