7-37
Cn029 Parameter Reset
【
5-6-14
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1
★
--
RS-485 CANopen EtherCAT Pi Pe Pt S T
0020H 201DH 201DH O O O O O
Setting Description:
Setting Description
0 Not Functioning
1 All Parameters returned to Factory Default Value
Cn030 Serialized Model Setting
【
1-1-3
】
Initial Value Unit Setting Range Effective Cn029 Reset
Factory Setting -- --
★
●
RS-485 CANopen EtherCAT Pi Pe Pt S T
0021H 201EH 201EH O O O O O
Setting Description: The setting value of this parameter is the same as the dn-08 display value, please refer to “1-1-3
Servo Driver and Servo Motor Matching Comparison Table"for the detailed setting method.
! Attention: Before the machine starts to operate, make sure to confirm the parameter setting value is the correct
Driver and Motor matching combination! When differing from actual combination, please reset or contact local
distributor!
Cn031.0 Fan operation setting (only applicable to models with a fan)
【
5-6-8
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 3 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0022H 201FH 201FH O O O O O
Setting Description:
Setting Description
0 Temperature Sensing Automatic Operation
1 Operates when Servo starts
2 Continuous Operation
3 Stop Operation