7-47
Cn063.0 Automatic mechanical suppression enablement selection
【
6-4
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 5 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0042H 203FH 203FH O O O O --
Setting Description:
Setting Description
0 Disable Automatic Detection of Mechanical Vibration Frequency
1
Enable Automatic Detection of First Set Mechanical Vibration
Frequency
2
Enable Automatic Detection of Second Set Mechanical Vibration
Frequency
3
Enable Automatic Detection of Third Set Mechanical Vibration
Frequency
4
Enable Automatic Detection of Fourth Set Mechanical Vibration
Frequency
5
Enable Automatic Detection of Firth Set Mechanical Vibration
Frequency
Cn064 Mechanical vibration detection level
【
6-4
】
Initial Value Unit Setting Range Effective Cn029 Reset
50 -- 1 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0043H 2040H 2040H O O O O -
Setting Description: The automatic detection level when executing Automatic Mechanical Vibration Suppression
(Cn063=1), the lower the value is, the more likely the noise is determined incorrectly, the
recommended setting is 50 or higher.
Cn065 Notch filter depth (first set)
【
6-4
】
Initial Value Unit Setting Range Effective Cn029 Reset
0 -- 0 ~ 1000 -- --
RS-485 CANopen EtherCAT Pi Pe Pt S T
0044H 2041H 2041H O O O O -
Setting Description: Used to adjust the frequency depth to be suppressed, the smaller the Cn065 value is, the deeper the
frequency depth to be suppressed. Users can adjust according to actual conditions.