8-112
(6) Object 605Ch: Disable option option code
INDEX 605C
h
Name Disable option option code
Object Code VAR
Data Type INTEGER 16
Access RW
PDO Mapping No
Valu e Ran ge
0: Disable drive, motor is free to rotate
1: Slow down on slow down ramp
Default Value 1
(7) Object 605Dh: Halt option code
INDEX 605D
h
Name Halt option code
Object Code VAR
Data Type INTEGER 16
Access RW
PDO Mapping No
Valu e Ran ge
1: Slow down on slow down ramp
2: Slow down on quick stop ramp
Default Value 1
(8) Object 6060h: Modes of operation
INDEX 6060
h
Name Modes of operation
Object Code VAR
Data Type INTEGER 8
Access RW
PDO Mapping Yes
Valu e Ran g e
0: No mode used
1Profile Position Mode
3Profile Velocity Mode
4 : Profile Torque Mode
6Homing Mode
8Cyclic synchronous position mode
9Cyclic synchronous velocity mode
A
Cyclic synchronous Torque mode
Default Value 8