HYDRAULIC DRIVE SYSTEM
6-3336” & 40” Toro GrandStand Service Manual
6
11. Capthewheelmotorttingssodebrisdoesnotenter
the system.
12. Attachthehydraulichosestotheowtestgauge
(Fig.538).
Note: Whenusingaowtestgaugethatisnotbi
directional,damagetotheowtestercould
occur if the machine is operated in reverse.
14. Run the machine for 2 minutes in forward (no load)
to purge air from the system.
15. Run the machine at full throttle (no load). Verify the
RPMwithatachometer:3200+ 150 RPMs. Do not
exceed 3600 RPM.
16. With the drive control fully forward, slowly tighten the
restriction valve until the gauge indicates 300 PSI
(21 bar) (Fig. 540).
Fig. 538 IMG-0916a
13. Open the restriction valve all the way (counter-
clockwise) (Fig. 539).
Fig. 539 IMG-0917a
Fig. 540 IMG-0921a
17. Recordtheowreadingfromthebi-directionalow
meter.Makeasecondowreadingat1100PSIand
record that reading (Fig. 541).
Fig. 541 IMG-0920a