CHASSIS
3-2936” & 40” Toro GrandStand Service Manual
3
39. Remove the two set screws securing the pump
pullies to the pump output shafts. Remove the pump
pullies, then remove the keys from the pump shaft
keyways (Fig. 112).
41. Remove both pumps, with hoses attached, from the
engine base (Fig. 114).
Fig. 112 DSCN-4080a
Fig. 114 DSCN-4083a
42. Remove the nut and lock washer securing the red
starter cable to the solenoid (Fig. 115).
Fig. 115 DSCN-4084a
40. Remove the four sets of carriage bolts, washers, and
nuts securing the pumps to the engine base (Fig.
113).
Fig. 113 DSCN-4079a