RemovingtheControlValve(continued)
g345780
Figure97
1.Spoolvalve
3.Flangeheadscrews
2.Magnetsupportbracket4.Frame
WARNING
Beforedisconnectingorperforminganyworkonthehydraulic
system,allpressureinthesystemmustberelieved.SeeRelieving
HydraulicSystemPressure(page5–3).
2.RemovethecontrolvalvefromtheframeusingFigure96andFigure97as
guides.
3.Ifhydraulicttingsaretoberemovedfromcontrolvalve,marktting
orientationtoallowcorrectassembly.
InstallingtheControlValve
1.Ifttingswereremoved,installttingstocontrolvalveusingmarksmade
duringtheremovalprocesstoproperlyorientatettings.
2.InstallthecontrolvalvetotheframeusingFigure96andFigure97asguides.
3.Makesurehydraulictankisfull.Addcorrectuidifnecessary(see
Operator
’sManual).
HydraulicSystem:ServiceandRepairs
Page5–126
Reelmaster
®
3100-D/3105-D
20252SLRevA