Multimeter
Obtainthistoollocally
Themetercantesttheelectrical
componentsandcircuitsforcurrent,
resistance,orvoltage.
Note:Useadigitalmultimeterwhen
testingtheelectricalcircuits.Thehigh
impedance(internalresistance)ofadigital
meterinthevoltagemodeensuresthat
theexcesscurrentisnotallowedthrough
themeter.Thisexcesscurrentcan
damagethecircuitsthatarenotdesigned
tocarryit.
BatteryTerminalProtector
ToroPartNo.107-0392
Usethisaerosolsprayonthebattery
terminals,ringterminals,andforkterminals
toreducecorrosionproblems.Applythe
terminalprotectortotheconnectionafter
yousecurethebatterycable,ringterminal,
orforkterminal.
BatteryHydrometer
Usethebatteryhydrometerwhen
measuringthespecicgravityofthe
batteryelectrolyte.Youcangetthistool
locally.
DielectricGel
ToroPartNo.107-0342
Usethedielectricgeltopreventcorrosion
ofunsealedconnectionterminals.T o
ensurecompletecoatingoftheterminals,
liberallyapplythegeltothecomponent
andwireharnessconnector,plugthe
connectorintothecomponent,unplugthe
connector,applythegeltobothsurfaces
again,andconnecttheharnessconnector
tothecomponentagain.Theconnectors
mustbefullypackedwithgelforeffective
results.
Note:Donotusethedielectricgelon
thesealedconnectionterminalsasthe
gelcanunseattheconnectorsealsduring
assembly.