Program 05-03-IP : System Timing Parameters – 03
05-03-IP SYS PAR
1 0 0 9 0 2 0 0
IP=Item Pointer (01-08)
Value for each Item
IP Value Default Item Description
01 0-1 1= 40/60 Make / Break Ratio
02 0-1 0= Yes Automatic Trunk Search
03 0-1 0= Voice Intercom Call Signalling Method
04 0-9 9= 9 PABX (Centrex) Outgoing Code
05 0-9 1= 1 Toll Access Code
06 2-4 2= 2 digits Station Numbering Plan
07 0-1 0= Steady Internal Dial Tone Pattern
08 0-9 0= Continuous ring Door Phone / ACP Ringing Frequency
Description:
01. Make/Break Ratio
This parameter permits the selection of a Make/Break Ratio for Dial Pulse signalling.
IP \ Value 0 1
05-03-01 33/66 40/60
02. Automatic Trunk Search
This parameter allows the system to search for an available trunk according to the assigned dial 9 trunk group when
automatic dialing features are used; i.e., Speed Dial, Save Redial, Redial, etc.
IP \ Value 0 1
05-03-02 Allowed Not Allowed
03. Intercom Call Signalling Method
This parameter selects the Intercom calling method. The user can still override this selection by dialing 3 after initiating
an intercom call. Individual stations can be set to automatic microphone switch-on in mode 46-st-03 and thus override
the system-wide ring method.
IP \ Value 0 1
05-03-03 Voice Signalling Ring Signalling
04. PABX (Centrex) Outgoing Code: (Refer to Program 35-TK-01)
This parameter assigns the PABX outgoing call access code for Redial and Save Redial when the system is installed
behind a PABX. It is used when Trunk Lines are set to be PABX lines in Mode 35-TK-01.
This assignment also enables the system to identify whether the user's dialing is a PABX's Intercom call or an
Outgoing call for toll restrictions. This Outgoing Code can be any one digit (0,1,2,3,4,5,6,7,8,9).