Program 05-04-IP : System Timing Parameters – 04
05-04-IP SYS PAR
4 1 0 0 0 1 0 0
IP=Item Pointer (01-08)
Value for each Item
IP Value Default Item Description
01 0-9 4= 9600 System Baud Rate Setting
02 0-1 1= Enable Dial 9 Flag
03 0-8 0= Warning Action for Call Duration Limiting
04 0-1 0= 12 Hours 12/24 Hours Clock
05 0-9 0= None SLT Hook flash Answer Delay
06 0-4 1= 200 Sets Speed Dialing Distribution
07 0-1 0= Disable Single Digit Intercom
08 0-4 0= 90v DC Message Waiting Method - Analog Phones
Description:
01. System Baud Rate Setting
This parameter sets the system Baud Rate of RS232 port for the following application:
1) SMDR= 9600 bps
2) SM5= 3600 bps
3) Software update = 57600 bps
4) G1E Monitor= 57600 bps (Refer to Program 05-24)
IP \ Value 0 1 2 3 4 5 6 7 8 Unit
05-04-01 1200 2400 3600 4800 9600 19200 38400 57600 115200 bps
02. Dial 9 Flag
This parameter sets if a station can access an outgoing line by dialing 9. If this parameter is disabled the station can
still access an outgoing line by pressing a line key on a Key phone or dial 8xx (xx is the trunk number).
IP \ Value 0 1
05-04-02 Dial 9 feature is enabled Dial 9 feature is disabled
03. Action for Call Duration Limiting
This parameter decides what action will be taken if a station has limit call duration enabled in Mode 40-nnnn-03.
Settings 0 to 3 are for outgoing calls only. The outside party will also hear the warning tone.
IP \ Value
Value Value Description
05-04-03
0 & 5 Continuous Warning Tone after Timeout
05-04-03 1 & 6 1 second Warning Tone for each cycle of Limit Call Duration
05-04-03 2 & 7
At 10 seconds before Timeout, 1 second Warning Tone
At 5 seconds before timeout, continuous Warning Tone,
At timeout the line is released.
05-04-03 3 & 8
At 1 minute before timeout, 1 second warning tone,
At 30 seconds before timeout, continuous warning tone
At timeout the line is released.