24.SPECIFICATIONS
117
24-6. General
Required power source - AC spec :100V to 240V AC ( 10% 15%)
[free power source 50/60Hz]
- DC spec :12V to 24V DC ( ± 15%)
(Depending on the request at the time of order)
Power consumption - AC spec: 15W (30VA) max.
- DC spec: 20W max.
Rush current (Typ) 15A, 5 msec.: 100V AC mean load state
(ordinary temperature, at cold-start time)
30A, 5 msec.: 200V AC mean load state
(ordinary temperature, at cold-start time)
Operating conditions Temperature-10 to +40
Humidity80%RH or below (non-condensing)
Warmup time 20 minutes
Dimensions 100W × 96H × 135Dmm (excluding projected parts)
Weight About 1kg