For example, if a single-character ID is defined as A, type 
OPEN A  
For example, if a multi-character ID is defined as 'RWY31', only the first 
character of the ID has to be given. Type 
OPEN R 
If ID is defined but forgotten, type 
OPEN *  
If the device type FS is included in the OPEN command, an ID is not 
needed. This device type can be used when there is only one FS11P 
sensor on the line. This command is similar to the OPEN * command 
with the exception that it only opens the FS11P command mode and not 
the other possible sensors on the line. Type 
OPEN FS 
If there are other sensors on the line with the same ID, the command 
mode of the FS11P sensor can be opened by including the device type FS 
with the ID. This command is similar to the OPEN ID command with 
the exception that it only opens the FS11P command mode and not the 
other sensors on the line with the same ID. For example, if a single-
character ID is defined as A, type 
OPEN FS A 
The FS11P sensor answers: 
FS11P-A LINE OPENED FOR OPERATOR COMMANDS 
For example, if a multi-character ID is defined as 'RWY31', type 
OPEN FS RWY31 
The FS11P sensor answers: 
FS11P-RWY31 LINE OPENED FOR OPERATOR COMMANDS 
 
If no input is given within 10 minutes, FS11P closes the line 
automatically. The timeout time is user selectable. 
If FS11P receives an OPEN command targeted to another device while 
in command mode, it executes a CLOSE command.