User's Guide _______________________________________________________________________
70 ___________________________________________________________________ M211107EN-C
For example, if a single-character ID is defined as A, type
OPEN A
For example, if a multi-character ID is defined as 'RWY31', only the first
character of the ID has to be given. Type
OPEN R
If ID is defined but forgotten, type
OPEN *
If the device type FS is included in the OPEN command, an ID is not
needed. This device type can be used when there is only one FS11P
sensor on the line. This command is similar to the OPEN * command
with the exception that it only opens the FS11P command mode and not
the other possible sensors on the line. Type
OPEN FS
If there are other sensors on the line with the same ID, the command
mode of the FS11P sensor can be opened by including the device type FS
with the ID. This command is similar to the OPEN ID command with
the exception that it only opens the FS11P command mode and not the
other sensors on the line with the same ID. For example, if a single-
character ID is defined as A, type
OPEN FS A
The FS11P sensor answers:
FS11P-A LINE OPENED FOR OPERATOR COMMANDS
For example, if a multi-character ID is defined as 'RWY31', type
OPEN FS RWY31
The FS11P sensor answers:
FS11P-RWY31 LINE OPENED FOR OPERATOR COMMANDS
If no input is given within 10 minutes, FS11P closes the line
automatically. The timeout time is user selectable.
If FS11P receives an OPEN command targeted to another device while
in command mode, it executes a CLOSE command.