User's Guide _______________________________________________________________________
84 ___________________________________________________________________ M211107EN-C
Example of status message:
!
FSA
FS11P SYSTEM STATUS: OK
Measurement unit: OK
Receiver:
Window cont: 0 backscatter: 35
DC saturation: 0 offset: -0.09
Transmitter:
Window cont: 0 backscatter: 8
Intensity: 162
Contamination compensation: ON
Temperatures (unit C):
surface: 22.8 CPU: 27.8 RX: 27.3 TX: 29.3 hood RX: 20.3
Hood TX: 21.0
Voltages:
+12V: 11.4 -12V:-11.3 VB: 12.5 VR: 6.7
Heater status:
Hood TX: OFF, hood RX: OFF, dew: OFF
Interface unit: OK
Temperatures (unit C):
CPU: 27.1, external: /////
Humidity: ////
Voltages:
+12V: 12.1 +12Vout: 0.0 PVin: 23.8 V5I: OFF
Background luminance sensor: OK
Window cont: 10
Contamination compensation: ON
Backscatter: 0
CPU: 26.2 hood: 24.6
Heater status: hood: OFF, dew: OFF
V5iso: ON
PWD STATUS
VAISALA PWD32 V 1.08 2009-10-30 SN:Z43107 ID STRING: 0
SIGNAL 167.03 OFFSET 154.74 DRIFT 8.94
REC. BACKSCATTER 14 CHANGE 0
TR. BACKSCATTER -1.3 CHANGE 0.0
LEDI -5.8 AMBL -1.0
VBB 12.6 P12 11.5 M12 -11.3
TS 22.2 FS TS 22.4
TB 22
TDRD 19 19 DRD 831 DRY 832.1
HARDWARE :
OK
WARNINGS :
OK
#CSUM∃−∗