S E R V I C I N G A N D I N S PE C T I O N
172
Venting the fuel system
1. Fill the fuel reservoir.
2. Switch the starting key to position I (operation) so that
the electrical fuel feed pump is working.
3. Wait 1 minute; the system will vent itself automatically.
4. The engine can now be started.
Fig. 73
Venting the fuel
system
I
0