S E R V I C I N G A N D I N S PE C T I O N
185
W L 3 0
Adding hydraulic uid
If the uid level is under the »Maximum« mark, add hydraulic
uid until the maximum level is reached.
1. Open the hydraulic uid ller neck cap Item 1 (Fig. 83).
2. Add hydraulic uid.
3. Check the hydraulic uid level.
4.
Add hydraulic uid until theuid level is at the »Maxi-
mum« mark.
5. Close the hydraulic oil ller neck cap Item 1 (Fig. 83).
Use the correct oil grade (reference Section 10.6,
page 155 »Specications and lling quantities«).
Open the hydraulic oil ller neck cap Item 1 (Fig. 83)
carefully so that the pressure can escape from the
reservoir.
Fig. 84
Hydraulic fluid dip
stick
Fig. 83
Ventilation filter
1