S E R V I C I N G A N D I N S PE C T I O N
186
Changing the hydraulic uid
WARNING
Burn hazard.
The operating temperature of the hydraulic sys-
tem is 93°C (200°F). Contact with skin will cause
severe burns.
Wear protective clothing.
Rinse affected areas with water immediately
and seek medical treatment.
ENVIRONMENTAL NOTE
Avoid environmental damage.
Collect old hydraulic uid and dispose of it in an
ecologically sound manner.
Refer to Section 10.6, page 155 »Specications
and lling quantities« to determine the necessary
container volume to avoid spillage.
1.
Stop the loader on a horizontal surface and set the park-
ing brake.
2.
Lower the loader lift arms and attachment to the ground
or work surface.
3. Stop the engine.
4.
Relieve residual hydraulic system pressure using the
procedure described in Section 8, page 126.
5.
Refer to Section 10.6, page 155 »Specications and
lling quantities« to determine the necessary container
volume to avoid spillage.
6. Remove the sealing plug (Fig. 85).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson WL 30 and is the answer not in the manual?

Wacker Neuson WL 30 Specifications

General IconGeneral
BrandWacker Neuson
ModelWL 30
CategoryFront End Loaders
LanguageEnglish

Related product manuals