Use
60 / 112 28.03.2022
Print a label
Identification options (ProofMaster PRO)
Programs menu options
Sorting options
Display settings of the current program
Administrator mode
User mode
Select
Back
Selected option
Favourites
Export
Import
Reset
Standby
Settings
5.5.2 Preset programs
The ProofMaster offers two types of programs:
• Preset programs: Programs predefined by the manufacturer
These are marked with the symbol.
• Customer programs (ProofMaster PRO): Free definition of all
parameters
Each newly created program is therefore a customer program.
Abbreviation Program name Info on program
P01 Universal 1bar Minimum pressure for delicate watches or watches that deform
significantly (e.g. plastic watches).
P02 Universal 2bar Universal test for all types of watches that are classified as waterproof.
Corresponds to the 2bar test as per ISO 22810:2010-4.4 and ISO
6425:2018-B.1.1.
P03 Universal 3bar For all types of watch that are classified as water-resistant to
3ATM/30m.
P04 Universal 5bar For all types of watch that are classified as water-resistant to
5ATM/50m.
P05 Universal 10bar For all types of watch that are classified as water-resistant to
10ATM/100m or more.
P11 Universal NoVac
1bar
Minimum pressure for delicate watches or watches that deform
significantly (e.g. plastic watches). Without vacuum test.